Kia Optima: Installation - Purge Control Solenoid Valve (PCSV). Repair procedures - Engine Control System - Engine Control/Fuel System - Kia Optima TF 2011-2019 Service ManualKia Optima: Installation

Х Install the component with the specified torques.
Х Note that internal damage may occur when the component is dropped. If the component has been dropped, inspect before installing.
Х Use care to keep foreign material out of the valve.
Х Install the purge control solenoid valve after lifting the support pin (A) of the bracket.

1. Installation is reverse of removal.

Purge control solenoid valve bracket installation bolt: 9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

Removal
1. Turn the ignition switch OFF and disconnect the battery negative (-) cable. 2. Disconnect the purge control solenoid valve connector (A). 3. ...

CVVT Oil Control Valve (OCV). Description and Operation
Description Continuous Variable Valve Timing (CVVT) system advances or retards the valve timing of the intake and exhaust valve in accordance with the ECM control signal which is calculated by ...

See also:

Release Residual Pressure in Fuel Line
Whenever the high pressure fuel pump, fuel pipe, delivery pipe, or injector is removed immediately after shutting off the engine, an ...

Installation
1. Installation is reverse of removal. Be careful of fuel pump direction (Refer to the groo ...

Blower Unit. Repair procedures
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad and heater blower unit.(Refer to HA group-heater unit) 3. Re ...