Kia Optima: Removal - CVVT Oil Control Valve (OCV). Repair procedures - Engine Control System - Engine Control/Fuel System - Kia Optima TF 2011-2026 Service ManualKia Optima: Removal

[Bank 1 / Intake]
1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2. Remove the OTS (A).
3. Disconnect the CVVT oil control valve connector (B).
4. Remove the installation bolt (C), and then remove the valve from the engine.

[Bank 1 / Exhaust]
1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2. Disconnect the CVVT oil control valve connector (A).
3. Remove the installation bolt (B), and then remove the valve from the engine.


Inspection
1. Turn the ignition switch OFF. 2. Disconnect the OCV connector. 3. Measure resistance between the OCV terminals 1 and 2. 4. ...

Installation
• Install the component with the specified torques. • Note that internal d ...