Kia Optima: Removal - Purge Control Solenoid Valve (PCSV). Repair procedures - Engine Control System - Engine Control/Fuel System - Kia Optima TF 2011-2026 Service ManualKia Optima: Removal

1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2. Disconnect the purge control solenoid valve connector (A).
3. Disconnect the vapor hoses (B) from the purge control solenoid valve.

4. Remove the valve from the bracket in the direction of the arrow.


Inspection
1. Turn the ignition switch OFF. 2. Disconnect the PCSV connector. 3. Measure resistance between the PCSV terminals 1 and 2. 4. ...

Installation
• Install the component with the specified torques. • Note that internal d ...