Kia Optima: Overdrive Clutch Control Solenoid Valve(OD/C_VFS). Description and Operation - 35R Clutch Control Solenoid Valve(35R/C_VFS). Description and Operation - Automatic Transaxle System - Kia Optima TF 2011-2026 Service ManualKia Optima: Overdrive Clutch Control Solenoid Valve(OD/C_VFS). Description and Operation

Description

Overdrive clutch control solenoid valve(OD/C_VFS) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the overdrive clutch.


Removal
Replacing an on/off solenoid valve (SS-A, SS-B) does not require additional hydraulic pressure adjustment; however, the hydraulic pre ...

Overdrive Clutch Control Solenoid Valve(OD/C_VFS). Specifications
Specifications Direct control VFS[35R/C]▷ Control type : Normal low type Control Pressure kpa(kgf/cm², psi) 500.14~9.81(5.1~0.1,72.54~1.42) Curren ...

See also:

Troubleshooting
Basic Troubleshooting Basic Troubleshooting Guide Customer Problem Analysis Sheet Basic Inspection ProcedureMeasuring Condition of Electronic Parts' Resistance The measured resistance at hi ...

Multimedia Jack. Schematic Diagrams
Circuit Diagram ...

Installation
1. Installation is reverse of removal. PCV Valve installation: 1.9 ~ 2.8 N.m (0.19 ~ 0.29 kgf.m, 1.4 ~ 2.1 lb-ft) ...