Kia Optima: Inspection - Evaporator Temperature Sensor. Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Optima TF 2011-2026 Service ManualKia Optima: Inspection

1. Ignition "OFF"
2. Disconnect evaporator temperature sensor.
3. Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

Specification

Specification
Evaporator core
temperature[°C(°F)]
Resistance[KΩ]
-10
43.35
0
27.62
10
18.07
20
12.11
30
8.30
40
5.81


Evaporator Temperature Sensor. Repair procedures
...

Replacement
1. Disconnect the negative (-) battery terminal. 2. Loosen the mounting screw and then remove the crash pad lower cover (A). 3. Remove the eva ...