Kia Optima: Inspection - Evaporator Temperature Sensor. Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Optima TF 2011-2022 Service ManualKia Optima: Inspection

1. Ignition "OFF"
2. Disconnect evaporator temperature sensor.
3. Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

Specification

Specification
Evaporator core
temperature[C(F)]
Resistance[KΩ]
-10
43.35
0
27.62
10
18.07
20
12.11
30
8.30
40
5.81


Evaporator Temperature Sensor. Repair procedures
...

Replacement
1. Disconnect the negative (-) battery terminal. 2. Loosen the mounting screw and then remove the crash pad lower cover (A). 3. Remove the eva ...

See also:

Front Strut Assembly Components and Components Location
Components 1. Strut assembly2. Insulator3. Bearing4. Spring upper pad5. Coil spring6. Dust cover7. Spring lower pad ...

High Voltage Shut-off Procedures
High Voltage Shut-off Procedures     Be sure to read and follow the “General Safety Information and Caution” before doing any work related with the high voltage sys ...

TPMS Receiver Description and Operation
Operation 1. General Function • Auto-locate/learn takes place only once per Ignition cycle. • On successful completion, 4 road wheel sensor ID''s, together with their respe ...