Kia Optima: Inspection - Evaporator Temperature Sensor. Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Optima TF 2011-2025 Service ManualKia Optima: Inspection

1. Ignition "OFF"
2. Disconnect evaporator temperature sensor.
3. Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

Specification

Specification
Evaporator core
temperature[°C(°F)]
Resistance[KΩ]
-10
43.35
0
27.62
10
18.07
20
12.11
30
8.30
40
5.81


Evaporator Temperature Sensor. Repair procedures
...

Replacement
1. Disconnect the negative (-) battery terminal. 2. Loosen the mounting screw and then remove the crash pad lower cover (A). 3. Remove the eva ...

See also:

Inspection
Brake Booster 1. Inspect the check valve in the vacuum hose, intensifier and the connecting section. ...

Installation
1. Reassemble the steering wheel remote control switch after connecting the connector. 2. Reassemble the steering wheel. 3. Reassemble the driver airbag ...

Weight Classification System (WCS). Description and Operation
Description In contrast to the initial one-stage airbag systems, newer restraint systems involve complex logic to select, or alternatively suppress, various levels of safety system deployment. In ...