Connector [CHTG-AG]

Pin
Description
Pin
Description
1
-
54
-
2
Line pressure control solenoid valve (LINE_VFS)
55
-
3
Torque converter control solenoid valve (T/CON_VFS)
56
-
4
35R clutch control solenoid valve (35R/C_VFS)
57
-
5
-
58
-
6
-
59
-
7
Inhibitor switch signal "S1"
60
-
8
Inhibitor switch signal "S2"
61
-
9
Inhibitor switch signal "S3"
62
-
10
Inhibitor switch signal "S4"
63
-
11
-
64
-
12
-
65
ON/OFF solenoid valve B(SS-B)
13
-
66
ON/OFF solenoid valve B(SS-A)
14
-
67
Battery (B+)
15
-
68
-
16
-
69
Oil temperature sensor (+)
17
-
70
-
18
-
71
-
19
-
72
-
20
-
73
Output speed sensor signal
21
-
74
Sports mode up switch
22
-
75
-
23
Underdrive brake control solenoid valve (UD/B_VFS)
76
-
24
26 brake control solenoid valve (26/B_VFS)
77
-
25
Overdrive clutch control solenoid valve (OD/C_VFS)
78
-
26
-
79
-
27
-
80
-
28
-
81
-
29
-
82
-
30
-
83
-
31
-
84
-
32
-
85
-
33
-
86
Solenoid supply power 1
34
-
87
Solenoid supply power 2
35
-
88
Battery (B+)
36
-
89
-
37
-
90
Output speed sensor power
38
-
91
Input speed sensor power
39
-
92
-
40
-
93
-
41
-
94
Input speed sensor signal
42
-
95
Sports mode down switch
43
-
96
-
44
Ground (Power 1)
97
-
45
Ground (Power 2)
98
-
46
Shift lock solenoid
99
-
47
-
100
-
48
Oil temperature sensor (-)
101
-
49
-
102
-
50
-
103
-
51
-
104
-
52
Sports mode select switch
105
-
53
-
 


1. TCM Connector and Terminal Function
...

TCM Terminal Input/ Output Signal
Connector [CHTG-AG] Pin Description Condition Input/output value Type Level 1 -   ...

See also:

Manual climate control system
To defog inside windshield 1. Select any fan speed except “0” position. 2. Select desired temperature. 3. Select the or position. 4. The outside (fresh) air will be selected automatically. ...

SS-B Solenoid Valve(ON/OFF). Schematic Diagrams
Circuit Diagram ...

Mode Selection
Controls the direction of air flow through the ventilation system. The air from outlet port flows at any mode. Close the ventilation outlets using the knob to block the air flow if you do not wan ...

Copyright © www.kiopman.com 2024