Specification
Air Conditioner
Item |
Specification |
|
Compressor |
Type |
6VSX16 (External variable displacement) |
Oil type & Capacity |
FD46XG(PAG) 100±10cc |
|
Pulley type |
6PK-TYPE |
|
Displacement |
160cc/rev |
|
Condenser |
Heat rejection |
14,400 ± 5% kcal/hr |
A/C Pressure transducer |
The method to measure the pressure |
Voltage = 0.00878835 * Pressure (psig) + 0.5 |
Expansion valve |
Type |
Block type |
Refrigerant |
Type |
R-134a |
Capacity [oz.(g)] |
19.4 ± 0.88 (550 ± 25) |
Blower Unit
Item |
Specification |
|
Fresh and recirculation |
Operating method |
Actuator |
Blower |
Type |
Sirocco |
Speed step |
Auto + 8 speed (Automatic), 1~8 speed (Manual) |
|
Speed control |
Power mosfet (Auto) , Resistor (Manual) |
|
Air filter |
Type |
Particle filter |
Heater And Evaporator Unit
Item |
Specification |
|
Heater |
Type |
Pin & Tube type |
Heating capacity |
4,850 - 5% kcal/hr |
|
Mode operating method |
Actuator |
|
Temperature operating method |
Actuator |
|
Evaporator |
Temperature control type |
Evaporator temperature sensor |
A/C ON/OFF [°C(°F)] |
ON : 2.1 ± 0.5 (35.7 ± 32.9) OFF: 0.6 ± 0.5 (33.0 ± 32.9) |
Inspection
1.
Check the bushing for wear and
deterioration.
2.
Check the rear lower arm for
deformation.
3.
Check the coil spring and spring
pad for deterior ...
Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the oil temperature
sensor connector.
3.
Measure resistance between sensor
signal terminal and sensor g ...
Shift Lock System
For your safety, the Automatic Transaxle has a shift lock system which prevents
shifting the transaxle out of P (Park) unless the brake pedal is depressed.
To shift the transaxle out of P (Park):
...