Whenever the vehicle battery is disconnected or discharged, or you use the emergency handle to operate the panoramaroof, you have to reset your panoramaroof system as follows :

1. Turn the ignition key to the ON position and then close the panoramaroof completely.
2. Release the panoramaroof control lever.
3. Press and hold the CLOSE button for more than 10 seconds until the panoramaroof has moved slightly.
4. Release the panoramaroof control lever.
5. Press and hold the CLOSE button once again within 3 seconds until the panoramaroof do as follows;
A. Tilt → Slide Open → Slide Close

Then release the lever.

6. Reset procedure of panorama system is finished.
Protecting Motor From Overheating

In order to protect the panoramaroof motor from overheating from continuous motor operation, the panoramaroof ECU controls the Run-time and Cool-time of the motor as follows:

1. The panoramaroof ECU detects the Run- time of motor
2. Motor can be operated continuously for the 1st run-time(120 ± 10sec.).
3. The continuous operation of motor stops after the 1st Run-time(120 ± 10sec.).
4. Then Motor is not operated for the 1st Cool-time(18 ± 2sec.).
5. Motor is operated for the 2nd Run-time(10 ± 2sec.) at the continued motor operation after 1st Cool-time(18 ± 2sec.)
6. The continuous operation of motor stops operating after the 2nd Run-time(10 ± 2sec.)
7. Motor is not operated for the 2nd Cool-time(18 ± 2sec.).
8. Motor repeats the 2nd run-time and 2nd cool-time at the continued motor operation.
A. In case that motor is not operated continuously, the run-time is increased.
B. The Run-Time of motor is initialized to "0" if the battery or fuse is reconnected after being disconnected, discharged or blown.

T1 : 120 ± 10 sec., T2 : 18 ± 2 sec.,T3 : 10 ± 2 sec., T4 : 18 ± 2 sec.

T1 : 120 ± 10 sec., T2 : 18 ± 2 sec.,

T3 : 10 ± 2 sec., T4 : 18 ± 2 sec.


Inspection
1. Disconnect the negative (-) battery terminal. 2. Remove the roof trim.(Refer to the BD group - "Roof trim") 3. Disconnect the panoram ...

Lighting System
...

See also:

Function
Wiper Control Washer Control Coupled With Wiper 1. Under IGN2 = ON, wiper LOW relay is turned ON after T2 from Washer switch ON if washer switch is ON for T1 and wipe ...

Removal
1. Disconnect the battery negative cable, and wait for at least three minutes before beginning work. 2. To remove the seat belt anchor pretensioner (C), keep on push ...

Electric WGT Control Actuator. Description and Operation
Desrcription The Electric WGT Control Actuator is installed on the turbocharger.It operates the vain in the Waste Gate Turbocharger (WGT) and regulates the compressed air amount by the ECM's P ...