Kia Optima: Replacement - Blower Resistor. Repair procedures - Blower - Heating,Ventilation, Air Conditioning - Kia Optima TF 2011-2026 Service ManualKia Optima: Replacement

1. Disconnect the negative (-) battery terminal.
2. Remove the main crash pad lower cover (A).

3. Disconnect the blower resistor connector (A) and then remove the blower resistor (B) after loosening the mounting screws.

4. Installation is the reverse order of removal.

Inspection
1. Measure terminal-to-terminal resistance of the blower resistor. 2. measured resistance is not within specification, the blower resistor must be replaced. (After re ...

Climate Control Air Filter. Description and Operation
Description This has particle filter which eliminates foreign materials and odor. The particle filter includes odor filter as well as conventional dust filter to ensure comfortable interior envi ...