Kia Optima: Line Pressure Control Solenoid Vale. Specifications - Automatic Transaxle Control System - Automatic Transaxle System - Kia Optima TF 2011-2022 Service ManualKia Optima: Line Pressure Control Solenoid Vale. Specifications

Specifications

Direct control VFS[LINE Pressure]

▷ Control type : Normal low type

Control Pressure kpa(kgf/cm², psi)
500.14~9.81(5.1~0.1,72.54~1.42)
Current value(mA)
50~850
 Internal resistance(Ω)
5.1


Line Pressure Control Solenoid Vale. Description and Operation
Description Line pressure control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the line pressure. ...

Line Pressure Control Solenoid Vale. Schematic Diagrams
Circuit Diagram ...

See also:

Disassembly
1. Remove the alternator cover (A) using a screw driver after loosening the nuts (B). 2. Remove the slip ring guide (A) and then loosen the ...

Canister Close Valve (CCV) Specifications
Specification ItemSpecificationCoil Resistance (?)19.8 ~ 21.8 [20°C(68°F) ...

Blind Spot Detection Variant Coding Description and Operation
Description The used radar frequency of BSD is two, "North America region" and "Except North America region". If it replaces BSD unit, BSD unit has to perform the procedure of variant coding. BSD ...