Kia Optima: Line Pressure Control Solenoid Vale. Specifications - Automatic Transaxle Control System - Automatic Transaxle System - Kia Optima TF 2011-2024 Service ManualKia Optima: Line Pressure Control Solenoid Vale. Specifications

Specifications

Direct control VFS[LINE Pressure]

▷ Control type : Normal low type

Control Pressure kpa(kgf/cm², psi)
500.14~9.81(5.1~0.1,72.54~1.42)
Current value(mA)
50~850
 Internal resistance(Ω)
5.1


Line Pressure Control Solenoid Vale. Description and Operation
Description Line pressure control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the line pressure. ...

Line Pressure Control Solenoid Vale. Schematic Diagrams
Circuit Diagram ...

See also:

Installation
1. Install the heater control unit. 2. Install the center fascia panel. 3. Install the crash pad garnish. ...

Transaxle Oil Temperature Sensor. Description and Operation
Description Transaxle oil temperature sensor monitors the automatic transaxle fluid's temperature and conveys the readings to TCM. It is an NTC (Negative Thermal Coefficient) sensor whose res ...

Consumer Assistance
Roadside Assistance is provided on all new 2006 model Kia Vehicles from the date the vehicle is delivered to the first retail buyer or otherwise put into use (in-service date), whichever is earlie ...