Kia Optima: Inspection - Ambient Sensor. Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Optima TF 2011-2023 Service ManualKia Optima: Inspection

1. Ignition "OFF"
2. Disconnect ambient temperature sensor.
3. Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature.

1. Sensor Ground
2. Ambient Sensor Signal

Specification

Ambient temperature
[°C(°F)]
Resistance between terminals 1and 2 (kΩ)
-30(-22)
480.41
-20(-4)
271.21
-10(14)
158.18
0 (32)
95.10
10 (50)
58.80
20 (68)
37.32
30(86)
23.76
40(104)
16.13
50(122)
10.95

4. If the measured resistance is not specification, substitute with a known-good ambient temperature sensor and check for proper operation.
5. If the problem is corrected, replace the ambient temperature sensor.

Ambient Sensor. Repair procedures
...

Replacement
1. Disconnect the negative (-) battery terminal. 2. Loosen the mounting bolts and then remove the under cover (A). 3. Disconnect the connector ...

See also:

Installation
1. Install the mirror assembly. 2. Install the mirror wiring cover and connector. ...

Installation
1. Install the power window switch module. 2. Install the door trim panel after reconnecting the relevant connectors ...

Specifications
Specifications Items Specifications Rated voltage DC 12V Operating temperature range -30°C ~ +80°C (-22 ~ +176°F) ...