Specifications
▷ Type: Hall effect sensor
Operation condition [°C(°F)] |
((-)40~150)) -40~302 |
|
Air gap(mm)in. |
(0.55~1) 0.0217~0.0394 |
|
Output voltage |
High |
1.18~1.68 |
Low |
0.59~0.84 |
Installation
•
Install the component with the specified
torques.
•
Note that internal damag ...
Injured person
A seat belt should be used when an injured person is being transported. When
this is necessary, you should consult a physician for recommendations. ...
Inspection
Radiator Cap Testing
1.
Remove the radiator cap, wet
its seal with engine coolant, and then install it on a pressure tester.
2.
Apply a pressure of 93.16 ~ 122.58k ...