Kia Optima: Removal
| 1. |
If the compressor is marginally
operable, run the engine at idle speed, and let the air conditioning work
for a few minutes, then shut the engine off. |
| 2. |
Disconnect the negative cable
from the battery. |
| 3. |
Recover the refrigerant with
a recovery/charging station |
| 4. |
Loosen the drive belt. (Refer
to EM group - "Drive belt")
|
| 5. |
Remove the bolts, then disconnect
the suction line (A) and discharge line (B) from the compressor. Plug or
cap the lines immediately after disconnecting them to avoid moisture and
dust contamination.
Tightening torque :
3.9~5.8 N.m(0.4 ~ 0.6 kgf.m, 2.9~4.3 Ib-ft)
|

|
| 6. |
Disconnect the compressor connector
(A), and then remove mounting bolts and the compressor (B).

|
1.
Make sure of the length of compressor
mounting bolts, and then tighten it A→B→C→D order.
Tightening torque :20.0~32.9N.m
(2.04~3.36kgf.m, 14.7~24 ...
See also:
Special Service Tools
Special tools
Tool(Number and Name)
Illustration
Use
09495 - 3P100
Band installer
Installation of hook type boot band.
...
Installation
1.
Apply a light coat of engine
oil to the oil cooler packing surface (A), and then install the oil cooler
with fix bolt (B).
Tightening torque:44.1
~ 53.9 N.m (4.5 ~ ...
Fuel Pressure Control Valve. Specifications
Specification
Item
Specification
Coil Resistance (Ω)
0.5 [20°C(68°F)
...