Kia Optima: Inspection - A/C Pressure Transducer. Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Optima TF 2011-2026 Service ManualKia Optima: Inspection

1. Measure the pressure of high pressure line by measuring voltage output between NO.1 and NO.2 terminals.

2. Inspect the voltage value whether it is sufficient to be regular value or not.


Voltage = 0.00878835 * Pressure + 0.5[PSIA]
3. If the measured voltage value is not specification, replace the A/C pressure transducer.

A/C Pressure Transducer. Repair procedures
...

Replacement
1. Disconnect the negative (-) battery terminal. 2. Recover the refrigerant with a recovery/charging station. 3. Disconnect the A/C pressure transduc ...

See also:

Inspection
1. Ignition "OFF" 2. Disconnect the connector of temperature control actuator. 3. Verify that the temperature control actuator operates to t ...

Specifications
Specifications Items Specifications Rated voltage DC 12V Operating temperature range -30°C ~ +80°C (-22 ~ +176°F) ...

Installation
1. Installation is the reverse of removal. • If you don't ...