Kia Optima: Purge Control Solenoid Valve (PCSV). Specifications - Engine Control System - Engine Control/Fuel System - Kia Optima TF 2011-2020 Service ManualKia Optima: Purge Control Solenoid Valve (PCSV). Specifications

Specification

Item
Specification
Coil Resistance (Ω)
19.0 ~ 22.0 [20°C(68°F)]


Purge Control Solenoid Valve (PCSV). Description and Operation
Description Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ...

Purge Control Solenoid Valve (PCSV). Schematic Diagrams
Circuit Diagram ...

See also:

Installation
1. Installation is the reverse of removal. After replacement or reinstallation procedure of the valve body assembly, ...

Inspection
1. Ignition "OFF". 2. Disconnect the intake actuator connector. 3. Verify that the actuator operates to the recirculation position when conn ...

Fuel Pressure Control Valve. Specifications
Specification Item Specification Coil Resistance (Ω) 0.5 [20°C(68°F) ...