Kia Optima: Inspection - Evaporator Temperature Sensor. Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Optima TF 2011-2019 Service ManualKia Optima: Inspection

1. Ignition "OFF"
2. Disconnect evaporator temperature sensor.
3. Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

Specification

Specification
Evaporator core
temperature[∞C(∞F)]
Resistance[KΩ]
-10
43.35
0
27.62
10
18.07
20
12.11
30
8.30
40
5.81


Evaporator Temperature Sensor. Repair procedures
...

Replacement
1. Disconnect the negative (-) battery terminal. 2. Loosen the mounting screw and then remove the crash pad lower cover (A). 3. Remove the eva ...

See also:

Installation
Х Install the component with the specified torques. Х Note that internal damag ...

Smart key. Repair procedures
Smart Key Smart Key Code Saving 1. Connect the DLC cable of GDS to the data link connector in driver side crash pad lower panel, turn the power on GDS. 2. Sel ...

Closing the trunk
To close, lower the trunk lid, then press down on it until it locks. To be sure the trunk lid is securely fastened, always check by trying to pull it up again. WARNING The trunk lid should be alw ...