Kia Optima: Inspection - Transmitter. Repair procedures - Keyless Entry And Burglar Alarm - Body Electrical System - Kia Optima TF 2011-2020 Service ManualKia Optima: Inspection

1. Check that the red light flickers when the door lock or unlock button is pressed on the transmitter.
2. Remove the battery (A) and check voltage if the red light doesn't flicker.

Standard voltage : 3V

3. Insert the battery (A) into the tester (09954-2P100).

4. Push the test button and If "0.00" is displayed on screen, it means that the battery voltage is 2V or less.
5. If "L" is displayed on screen, it means that the battery is low power and it needs to replace.
6. To prevent the discharge of electricity, turn the tester power off.
7. Replace the transmitter battery with a new one, if voltage is low power then try to lock and unlock the doors with the transmitter by pressing the lock or unlock button five or six times.
8. If the doors lock and unlock, the transmitter is O.K, but if the doors don't lock and unlock, register the transmitter code, then try to lock and unlock the doors.
9. If the doors lock and unlock, the transmitter is O.K, but if the doors don't lock and unlock, replace the transmitter.
An inappropriately disposed battery can be harmful to the environment and human health.

Dispose the battery according to your local law(s) or regulation.


Transmitter. Repair procedures
...

Transmitter Code Registration (Using Code Saver)
1. Open Door. 2. Connect POWER (B+) and GND, signal line of Code Saver. 3. If connection is normal, signal line is activated and RED LED turns ON. ...

See also:

Headrest
The rear seat(s) is equipped with headrests in the outboard seating positions for the occupant's safety and comfort. The headrest not only provides comfort for passengers, but also helps prot ...

Seat Belt Pretensioner (BPT) Description and Operation
Description The Seat Belt Pretensioners (BPT) are installed inside Center Pillar (LH & RH). When a vehicle crashes with a certain degree of frontal impact, the pretensioner seat belt helps ...

NVLD(Natural Vacuum Leakage Detection) Specifications
Specification Pressure [kPa (kgf/cm?, in H2O)Output Voltage (V)-6.67 (-0.068, -26.8)0.502.5+6.67 (0.068, 26.8)4.5 ...

Copyright © www.kiopman.com 2020