1. |
Insert a thin stick (A) into the PCV valve (B) from
the threaded side to check that there is the plunger movement.
|
Removal
1.
Turn the ignition switch OFF and disconnect the battery
negative (-) cable.
2.
Disconnect the crankshaft position sensor connector
(A).
...
Inspection
1.
Immerse the thermostat in water
and gradually heat the water.
2.
Check the valve opening temperature.
Valve opening temperature:
82 ± 1.5°C (17 ...
Disassembly
1.
Disconnect the negative (-) battery
terminal.
2.
Remove the front tire (A) from
hub assembly.
Tightening torque :
10~15N.m (9~11kgf.m, 7.37~11lbf.ft ...