Kia Optima: Torque Converter Control Solenoid Valve (T/CON_VFS). Specifications - Automatic Transaxle Control System - Automatic Transaxle System - Kia Optima TF 2011-2019 Service ManualKia Optima: Torque Converter Control Solenoid Valve (T/CON_VFS). Specifications

Specifications

Direct control VFS[T/CON]

▷ Control type : Normal low type

Control Pressure kpa(kgf/cm², psi)
9.81~500.14(0.1~5.1,1.42~72.54)
Current value(mA)
50~850
 Internal resistance(Ω)
5.1


Torque Converter Control Solenoid Valve (T/CON_VFS). Description and Operation
Description Torque converter control solenoid valve (T/CON_VFS) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the torque conver ...

Torque Converter Control Solenoid Valve (T/CON_VFS). Schematic Diagrams
Circuit Diagram ...

See also:

Operation
Operating Procedure 1. Suspension angle change resulted from vehicle's load change. 2. Sensor angle change. 3. Microprocessor calculates necessary ...

Ambient Sensor. Description and Operation
Description 1. The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increas ...

Installation
1. Install the wiper motor. 2. Install the crank arm. Tighting torque:24.5 ~ 26.4Nm (2.5 ~ 2.7, kgf.m, 18.0 ~ 19.5 lbf.ft) ...