Specifications
Direct control VFS[LINE Pressure]
Control type : Normal high type
Control Pressure kpa
(kgf/cm?, psi)
500.14 ~ 9.81
(5.1 ~ 0.1, 72.54 ~ 1.42)
Current value (mA)
50 ~ 850
 Internal resistance (?)
5.1

Line Pressure Control Solenoid Vale Description and Operation
Description Line pressure control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure to the line pressure. ...

Line Pressure Control Solenoid Vale Schematic Diagrams
Circuit Diagram ...

See also:

Components and Components Location
Components 1. Steering wheel 2. Steering column 3. ECU 4. Motor 5. Steering gear box MDPS Circuit Diagram Harness Connector ...

Removal
1. Disconnect the vapor hose (A). 2. Remove the PCV valve (B). ...

Intake Actuator Description and Operation
Description 1. The intake actuator is located at the blower unit. 2. It regulates the intake door by signal from control unit. 3. Pressing the intake selection switch will shift between re ...