Kia Optima: Inspection - Power Mosfet. Repair procedures - Blower - Heating,Ventilation, Air Conditioning - Kia Optima TF 2011-2020 Service ManualKia Optima: Inspection

1. Ignition "ON"
2. Manually operate the control switch and measure the voltage of blower motor.
3. Select the control switch to raise voltage until high speed.

Specification

Specification
Fan
Motor Voltage
Manual
First speed
3.8 ±0.5V
Second speed
5.0 ±0.5V
Third speed
6.2 ±0.5V
Fourth speed
7.4 ±0.5V
Fifth speed
8.6 ±0.5V
Sixth speed
9.8 ±0.5V
Seventh speed
11.0 ±0.5V
eighth speed
Battery

*AUTO COOLING: Auto speed (4.5V~B+)

*AUTO HEATING: Auto speed (4.5V~11.0V)
4. If the measured voltage is not specification, substitute with a known-good power mosfet and check for proper operation.
5. If the problem is corrected, replace the power mosfet.

Power Mosfet. Repair procedures
...

Replacement
1. 1. Disconnect the negative (-) battery terminal. 2. Remove the main crash pad lower cover (A). 3. Disconnect the power mosfet connector ...