Kia Optima: Inspection - Ambient Sensor. Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Optima TF 2011-2019 Service ManualKia Optima: Inspection

1. Ignition "OFF"
2. Disconnect ambient temperature sensor.
3. Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature.

1. Sensor Ground
2. Ambient Sensor Signal

Specification

Ambient temperature
[°C(°F)]
Resistance between terminals 1and 2 (kΩ)
-30(-22)
480.41
-20(-4)
271.21
-10(14)
158.18
0 (32)
95.10
10 (50)
58.80
20 (68)
37.32
30(86)
23.76
40(104)
16.13
50(122)
10.95

4. If the measured resistance is not specification, substitute with a known-good ambient temperature sensor and check for proper operation.
5. If the problem is corrected, replace the ambient temperature sensor.

Ambient Sensor. Repair procedures
...

Replacement
1. Disconnect the negative (-) battery terminal. 2. Loosen the mounting bolts and then remove the under cover (A). 3. Disconnect the connector ...

See also:

Head Lamp Aiming Instructions
<Mechanical aiming> The head lamps should be aimed with the proper beam-setting equipment, and in accordance with the equipment manufacturer's instructions. ...

Dimensions Projected
1. These are the dimensions measured when the measurement points are projected from the vehicle's surface, and are the reference dimensions used for used for body alterations ...

Inspection
1. Check the signal waveform of the CMPS and CKPS using the GDS. Specification: Refer to “Wave Form” ...