Inspection
Power Relay Test (Type B)Check for continuity between the terminals.
A : Two turn unlock relay1. | There should be continuity between the No.30 and No.87 terminals when power and ground are connected to the No.85 and No.86 terminals. |
2. | There should be continuity between
the No.30 and No.87 terminals when power is disconnected.
|
Replacement
1.
Disconnect the negative (-) battery
terminal.
2.
Remove the crash pad.(Refer
to BD group - "Crash Pad")
3.
Disconnect the Intake actu ...
Installation
1.
Remove the ignition key from
the vehicle.
2.
Disconnect the battery negative
cable from battery and wait for at least three minutes before beginning
work.
...
Heater & A/C Control Unit(Dual). Components and Components Location
Components
Control Panel
Connector pin function
Connector
PIN NO.
Function
Connector
PIN NO.
Function
...