Kia Optima: Refrigerant line. Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Optima TF 2011-2024 Service ManualKia Optima: Refrigerant line. Repair procedures

Replacement

1. Discharge refrigerant from refrigeration system.
2. Replace faulty tube or hose.
Cap the open fittings immediately to keep moisture or dirt out of the system.
3. Tighten joint of bolt or nut to specified torque.
Connections should not be torque tighter than the specified torque.
Part tightened
N.m
kgf.m
lb-ft
Condenser - Discharge hose
3.9~5.9
0.4~0.6
2.9~4.3
Condenser - Liquid tube
Compressor - Discharge hose
3.9~5.9
0.4~0.6
2.9~4.3
Compressor - Suction hose
Expansion valve - Evaporator
7.8~11.7
0.8~1.2
5.7~8.6

4. Evacuate air in refrigeration system and charge system with refrigerant.

Specified amount 550 ± 25g (19.4 ± 0.88 oz.)
5. Inspect for leakage of refrigerant.

Using a gas leak detector, check for leakage of refrigerant.

6. Inspect A/C operation.

Refrigerant line. Components and Components Location
Component Location ...

Compressor. Components and Components Location
Components 1. Screw 2. Bolt 3. Disc & Hub Assembly 4. Retainer Ring 5. Pulley 6. Connector Bracket 7. Screw 8. Compressor Assembly ...

See also:

To temporarily accelerate with the cruise control on
If you want to speed up temporarily when the cruise control is on, depress the accelerator pedal. Increased speed will not interfere with the cruise control operation or change the set speed. To ...

Removal
1. Release the residual pressure in fuel line (Refer to “Release Residual Pressure in Fuel Line” in this group). 2. Remove the fuel pump service cover (A) in the ...

Description and Operation
Description System OverviewThe System offers the following features: - Human machine interface through a 1-stage button, for terminal switching and engine start. - Co ...