Kia Optima: Inspection - Evaporator Temperature Sensor. Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Optima TF 2011-2024 Service ManualKia Optima: Inspection

1. Ignition "OFF"
2. Disconnect evaporator temperature sensor.
3. Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

Specification

Specification
Evaporator core
temperature[°C(°F)]
Resistance[KΩ]
-10
43.35
0
27.62
10
18.07
20
12.11
30
8.30
40
5.81


Evaporator Temperature Sensor. Repair procedures
...

Replacement
1. Disconnect the negative (-) battery terminal. 2. Loosen the mounting screw and then remove the crash pad lower cover (A). 3. Remove the eva ...

See also:

Replacements
Movable glass Replacement 1. Open the movable glass fully. 2. Remove the folding cover (A). 3. After loosening the mounting screws, then remove the ...

Before Starting
Close and lock all doors. Position the seat so that all controls are easily reached. Adjust the inside and outside rearview mirrors. Be sure that all lights work. Check all gauges. Check ...

Why didn’t my air bag go off in a collision? (Inflation and non-inflation conditions of the air bag)
There are many types of accidents in which the air bag would not be expected to provide additional protection. These include rear impacts, second or third collisions in multiple impact accidents, ...

Copyright © www.kiopman.com 2024