Kia Optima: Adjustment - Electric WGT Control Actuator. Repair procedures - Engine Control System - Engine Control/Fuel System - Kia Optima TF 2011-2024 Service ManualKia Optima: Adjustment

1. Check that the waste gate turbo charger is cool enough to work.
2. Turn the ignition switch to OFF position.
3. Connect the diagnostic tool to DLC connector (16 pin) under the driver side instrument panel.
4. Turn the ignition switch ON position.
Do not start the engine.
5. Select VIN or Vehicle on the initial screen.
6. Enter "Engine Control" menu after slelecting vehicle information (Vehicle model, Model year, Engine type) or entering the VIN number.
7. Check " Adaption value for the lower mechancal stop of EWGA" after selecting "Current Data" menu.

Specified voltage value: 4.1 ~ 4.3 V

8. If the voltage value measured is not within the specified voltage value, adjust the EWGA rod length. But, if no, no further procedure is required.
(1) Loosen the rod end lock nut (A) and remove the C-ring (B).
(2) Adjust the rod end part (C) by rotating it clockwise (D) or counterclockwise (E) to satisfy the specification.
A. If output voltage. 4.3 V

: Turn it clockwise (D)

B. If output voltage < 4.1 V

: Turn it counterclockwise (E)

Turning angle
Changing level of the adaption value (V)
0.5 turn (180°)
 0.15 ~ 0.20
1 turn (360°)
 0.30 ~ 0.40

9. Install the rod end part (C) to the turbo charger lever (D) temporarily. Don't tighten the rod end lock nut (A).
10. Turn the ignition switch ON/OFF 5 times. But hold 5 seconds at each IG ON or OFF state.
Turn the ignition switch ON/OFF repeatedly until the changing value of " Adaption value for the lower mechancal stop of EWGA" is within 0.05V.

When turning the ignition switch ON or OFF once, maximum changing level of the adaption value : Max. ± 0.05V
11. If the voltage value measured is not within the specified voltage value, repeat 8~10 procedures untill the voltage value is within the specified voltage value.

Specified voltage value : 4.1 ~ 4.3 V
12. Check that " Adaption value for the lower mechancal stop of EWGA" is within the specified voltage value.
13. If it is within the specified voltage value, install the turbo charger lever (D) and the rod end part (C).
Be careful not to remove the washer (E).
14. Tighten the rod end locking nut (A). The turbo charger lever (D) side and the rod end part (C) side should be parallel at this time.
15. Install the C-ring (B).


Installation
1. Installation is the reverse order of removal. ...

RCV Control Solenoid Valve. Description and Operation
Description RCV (Recirculation Valve) Control Solenoid Valve is installed on the intercooler inlet pipe and operates the RCV actuator which controls the by-pass passage of the turbocharger comp ...