Special Service Tools |
Tool Name / Number | Illustration | Description |
RKE Battery Checker 09954-2P100 | Measuring the RKE battery voltage |
Personal Protective Equipment |
Name | Illustration | Description |
Insulation glove | Used when inspecting or working on the high voltage components [Insulation performance : 1000V / 300A or above] | |
Insulation shoes | Used when inspecting or working on the high voltage components | |
Insulation clothes | ||
Insulation helmet | ||
Safety glasses | Used in the case below • During Removal & installation or inspection of the high voltage battery terminals or wiring, which spark might happen. • During working on the high voltage battery pack assembly. | |
Face shield | ||
Insulation mat | Putting the removed high voltage components on the insulation mat to prevent safety accidents. | |
Insulation sheet | Covering
the high voltage components with insulation sheet to prevent people who don’t wear the personal protective equipment from safety accidents. |
Installation
•
Install the component with the specified
torques.
•
Note that internal damag ...
Front Strut Assembly Repair procedures
Replacement
1.
Remove the front wheel & tire.
Tightening torque:
88.3 ~ 107.9N.m(9.0 ~ 11.0kgf.m, 65.1 ~ 79.6lb-ft)
Be careful not to damage to the hub bolt ...
Removal
1.
Turn ignition switch OFF and
disconnect the negative (-) battery cable.
2.
Remove the air duct (B) and air
cleaner assembly (A).
3.